HP Servers
Template SNMP HP Server Summary exp
Template SNMP HP Server Summary exp
HP Servers
HP Array Controller
HP Fan Summary
HP Logical Drive
HP Physical Drive
HP System Summary
HP Temperature Sensor
HP Termal Summary
-
Cpu Fun(s) Status
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.5.0
cpqHeThermalCpuFanStatus.0
60
90
365
0
3
0
0
0
0
1
0
0
161
The status of the processor fan(s) in the system.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
All fans are operating properly.
failed(4)
A fan is not operating properly.
The system will be shutdown if the failed(4) condition occurs.
0
HP Termal Summary
HP SNMP Agent Condition
-
Resilient Memory Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.14.4.0
cpqHeResilientMemCondition.0
600
90
365
0
3
0
0
0
0
1
0
0
161
This value specifies the current condition of the Advanced Memory Protection subsystem.
The following states are supported:
other(1)
The system does not support fault tolerant memory or the
state cannot be determined by the Management Agent.
ok(2)
This system is operating normally.
degraded(3)
The system is running in a degraded state because the
Advanced Memory Protection subsystem has been engaged.
0
HP System Summary
HP SNMP Agent Condition
-
Server Condition
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.1.3.0
cpqHeMibCondition.0
60
90
365
0
3
0
0
0
0
1
0
0
161
The overall condition.
This object represents the overall status of the server health system represented by this MIB.
0
HP System Summary
HP SNMP Agent Condition
-
System Fun(s) Status
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.4.0
cpqHeThermalSystemFanStatus.0
60
90
365
0
3
0
0
0
0
1
0
0
161
The status of the fan(s) in the system.
This value will be one of the following:
other(1)
Fan status detection is not supported by this system or driver.
ok(2)
All fans are operating properly.
degraded(3)
A non-required fan is not operating properly.
failed(4)
A required fan is not operating properly.
If the cpqHeThermalDegradedAction is set to shutdown(3) the
system will be shutdown if the failed(4) condition occurs.
0
HP Termal Summary
HP SNMP Agent Condition
-
System Temperature Status
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.3.0
cpqHeThermalTempStatus.0
60
90
365
0
3
0
0
0
0
1
0
0
161
The status of the system's temperature sensors:
This value will be one of the following:
other(1)
Temp sensing is not supported by this system or driver.
ok(2)
All temp sensors are within normal operating range.
degraded(3)
A temp sensor is outside of normal operating range.
failed(4)
A temp sensor detects a condition that could permanently
damage the system.
The system will automatically shutdown if the failed(4) condition
results, so it is unlikely that this value will ever be returned
by the agent. If the cpqHeThermalDegradedAction is set to
shutdown(3) the system will be shutdown if the degraded(3)
condition occurs.
0
HP Termal Summary
HP SNMP Agent Condition
-
Termal Condition
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.1.0
cpqHeThermalCondition.0
60
90
365
0
3
0
0
0
0
1
0
0
161
This value specifies the overall condition of the system's
thermal environment.
0
HP Termal Summary
HP SNMP Agent Condition
Array Controller Index
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.3.2.2.1.1.1
snmp.discovery.v1
3600
0
0
0
0
0
161
0
7
Array Controller Index.
This value is a logical number whose meaning is OS dependent.
Each physical controller has one unique controller number
associated with it.
Drive Array Controller {#SNMPINDEX} Condition
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.3.2.2.1.1.6.{#SNMPINDEX}
cpqDaCntlrCondition.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
0
HP Array Controller
HP SNMP Agent Condition
Drive Array Controller {#SNMPINDEX} Firmware Revision
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.1.1.3.{#SNMPINDEX}
cpqDaCntlrFWRev.["{#SNMPINDEX}"]
9600
7
365
0
4
0
0
0
0
1
0
0
161
Array Controller Firmware Revision.
The firmware revision of the drive array controller. This value can be used to help identify a particular revision of the controller.
0
HP Array Controller
Drive Array Controller {#SNMPINDEX} Model
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.1.1.2.{#SNMPINDEX}
cpqDaCntlrModel.["{#SNMPINDEX}"]
9600
30
365
0
3
0
0
0
0
1
0
0
161
Array Controller Model.
The type of controller card.
0
HP Array Controller
{Template SNMP HP Server Summary exp:cpqDaCntlrCondition.["{#SNMPINDEX}"].last(0)}<>2
{HOST.NAME}: Drive Array Controller {#SNMPINDEX} Condition is Not OK
0
4
0
Drive Array Logical Drive Performance
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.3.2.8.1.1.1
snmp.discovery.v5
3600
0
0
0
0
0
161
0
7
Drive Array Logical Drive {#SNMPINDEX} Avg Queue Depth
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.8.1.1.5.{#SNMPINDEX}
cpqDaLogDrvPerfAvgQueueDepth.["{#SNMPINDEX}"]
60
90
365
0
3
0
0
0
0
1
0
0
161
Array Logical Drive Performance Monitor Average Queue Depth.
This value indicates the average command queue depth of the logical volume.
0
HP Logical Drive
Drive Array Logical Drive Summary
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.3.2.3.1.1.2
snmp.discovery.v4
3600
0
0
0
0
0
161
0
7
Drive Array Logical Drive {#SNMPINDEX} Avg Latency
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.7.1.1.7.{#SNMPINDEX}
cpqDaCntlrPerfAvgLatency.["{#SNMPINDEX}"]
60
90
365
0
0
ms
0
0
0
0
0.01
0
0
161
Array Controller Performance Monitor Average Command Latency.
This value shows the average command latency for this sample in 1/10,000 second units.
0
HP Logical Drive
Drive Array Logical Drive {#SNMPINDEX} Condition
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.3.2.3.1.1.11.{#SNMPINDEX}
cpqDaLogDrvCondition.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
The Logical Drive condition.
This value represents the overall condition of this logical drive and any associated physical drives.
0
HP Logical Drive
HP SNMP Agent Condition
Drive Array Logical Drive {#SNMPINDEX} Fault Tolerance
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.3.1.1.3.{#SNMPINDEX}
cpqDaLogDrvFaultTol.["{#SNMPINDEX}"]
7200
90
365
0
3
0
0
0
0
1
0
0
161
Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive. The following values are valid for the Logical Drive Fault Tolerance:
None (2)
Fault tolerance is not enabled. If a physical drive reports
an error, the data cannot be recovered by the drive array
controller.
Mirroring (3)
For each physical drive, there is a second physical drive
containing identical data. If a drive fails, the data can be
retrieved from the mirror drive.
Data Guard (4)
One of the physical drives is used as a data guard drive and
contains the exclusive OR of the data on the remaining drives.
If a failure is detected, the drive array controller rebuilds
the data using the data guard information plus information
from the other drives.
Distributed Data Guard (5)
Distributed Data Guarding, sometimes referred to as RAID 5,
is similar to Data Guarding, but instead of storing the parity
information on one drive, the information is distributed across
all of the drives. If a failure is detected, the drive array
controller rebuilds the data using the data guard information
from all the drives.
Advanced Data Guarding (7)
Advanced Data Guarding (RAID ADG) is the fault tolerance method
that provides the highest level of data protection. It
'stripes' data and parity across all the physical drives in the
configuration to ensure the uninterrupted availability of
uncorrupted data. This fault-tolerance method is similar to
distributed data guard (RAID 5) in that parity data is
distributed across all drives in the array, except in RAID ADG
the capacity of multiple drives is used to store parity data.
Assuming the capacity of 2 drives is used for parity data,
this allows continued operation despite simultaneous failure of
any 2 drives in the array, whereas RAID 4 and RAID 5 can only
sustain failure of a single drive.
0
HP Logical Drive
HP SNMP Logical Drive Fault Tolerance
Drive Array Logical Drive {#SNMPINDEX} Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.3.1.1.4.{#SNMPINDEX}
cpqDaLogDrvStatus.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
Logical Drive Status.
The logical drive can be in one of the following states:
Ok (2)
Indicates that the logical drive is in normal operation mode.
Failed (3)
Indicates that more physical drives have failed than the
fault tolerance mode of the logical drive can handle without
data loss.
Unconfigured (4)
Indicates that the logical drive is not configured.
Recovering (5)
Indicates that the logical drive is using Interim Recovery Mode.
In Interim Recovery Mode, at least one physical drive has
failed, but the logical drive's fault tolerance mode lets the
drive continue to operate with no data loss.
Ready Rebuild (6)
Indicates that the logical drive is ready for Automatic Data
Recovery. The physical drive that failed has been replaced,
but the logical drive is still operating in Interim Recovery
Mode.
Rebuilding (7)
Indicates that the logical drive is currently doing Automatic
Data Recovery. During Automatic Data Recovery, fault tolerance
algorithms restore data to the replacement drive.
Wrong Drive (8)
Indicates that the wrong physical drive was replaced after a
physical drive failure.
Bad Connect (9)
Indicates that a physical drive is not responding.
Overheating (10)
Indicates that the drive array enclosure that contains the
logical drive is overheating. The drive array is still
functioning, but should be shutdown.
Shutdown (11)
Indicates that the drive array enclosure that contains the
logical drive has overheated. The logical drive is no longer
functioning.
Expanding (12)
Indicates that the logical drive is currently doing Automatic
Data Expansion. During Automatic Data Expansion, fault
tolerance algorithms redistribute logical drive data to the
newly added physical drive.
Not Available (13)
Indicates that the logical drive is currently unavailable.
If a logical drive is expanding and the new configuration
frees additional disk space, this free space can be
configured into another logical volume. If this is done,
the new volume will be set to not available.
Queued For Expansion (14)
Indicates that the logical drive is ready for Automatic Data
Expansion. The logical drive is in the queue for expansion.
0
HP Logical Drive
HP SNMP Agent LogDrv Status
{Template SNMP HP Server Summary exp:cpqDaLogDrvStatus.["{#SNMPINDEX}"].last(0)}>2
{HOST.NAME}: Drive Array Logical Drive {#SNMPINDEX} Status Changed
0
3
0
Drive Array Physical Drive Summary
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.3.2.5.1.1.2
snmp.discovery
3600
0
0
0
0
0
161
0
7
Drive Array Physical Drive {#SNMPINDEX} Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.37.{#SNMPINDEX}
cpqDaPhyDrvCondition.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
0
HP Physical Drive
HP SNMP Agent PhyDrv Status
Drive Array Physical Drive {#SNMPINDEX} Reads/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.11.{#SNMPINDEX}
cpqDaPhyDrvReads.["{#SNMPINDEX}"]
60
30
365
0
3
reads/s
1
0
0
0
1
0
0
161
0
HP Physical Drive
Drive Array Physical Drive {#SNMPINDEX} Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.6.{#SNMPINDEX}
cpqDaPhyDrvStatus.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
Physical Drive Status.
This shows the status of the physical drive.
The following values are valid for the physical drive status:
Other (1)
Indicates that the instrument agent does not recognize
the drive. You may need to upgrade your instrument agent
and/or driver software.
Ok (2)
Indicates the drive is functioning properly.
Failed (3)
Indicates that the drive is no longer operating and
should be replaced.
Predictive Failure(4)
Indicates that the drive has a predictive failure error and
should be replaced.
Erasing(5)
Indicates that the drive is being erased.
Erase Done(6)
Indicates that the drive has been erased and is now in an
offline state.
Erase Queued(7)
Indicates that an erase operation is currently queued for
the drive.
0
HP Physical Drive
Drive Array Physical Drive {#SNMPINDEX} Writes/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.13.{#SNMPINDEX}
cpqDaPhyDrvWrites.["{#SNMPINDEX}"]
60
30
365
0
3
writes/s
1
0
0
0
1
0
0
161
0
HP Physical Drive
{Template SNMP HP Server Summary exp:cpqDaPhyDrvCondition.["{#SNMPINDEX}"].last(0)}<>2
{HOST.NAME}: Drive Array Physical Drive {#SNMPINDEX} Condition is Not OK
0
4
0
Drive Array Physical Drive {#SNMPINDEX} Writes and Reads/Sec
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
0
0
0
0
0
5
3333FF
0
2
0
-
Template SNMP HP Server Summary exp
cpqDaPhyDrvReads.["{#SNMPINDEX}"]
1
5
00C800
0
2
0
-
Template SNMP HP Server Summary exp
cpqDaPhyDrvWrites.["{#SNMPINDEX}"]
Fault Tolerant Fan Condition
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.6.2.6.7.1.2
snmp.discovery.v2
3600
0
0
0
0
0
161
0
7
Fault Tolerant Fan {#SNMPINDEX} Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.6.7.1.9.{#SNMPINDEX}
cpqHeFltTolFanCondition.["{#SNMPINDEX}"]
600
7
365
0
3
0
0
0
0
1
0
0
161
The condition of the fan.
This value will be one of the following: other(1)
Fan status detection is not supported by this system or driver.
ok(2)
The fan is operating properly.
degraded(2)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly.
0
HP Fan Summary
HP SNMP Agent Condition
Fault Tolerant Fan {#SNMPINDEX} Locale
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.7.1.3.{#SNMPINDEX}
cpqHeFltTolFanLocale.["{#SNMPINDEX}"]
86400
7
30
0
3
0
0
0
0
1
0
0
161
This specifies the location of the fan in the system.
0
HP Fan Summary
HP SNMP Agent Locale
Power Supply Condition
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.6.2.9.3.1.2
snmp.discovery.v6
3600
0
0
0
0
0
161
0
7
Power Supply {#SNMPINDEX} Condition
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.9.3.1.4.{#SNMPINDEX}
cpqHeFltTolPowerSupplyCondition.["{#SNMPINDEX}"]
600
90
365
0
3
0
0
0
0
1
0
0
161
The condition of the power supply.
This value will be one of the following:
other(1)
The status could not be determined or not present.
ok(2)
The power supply is operating normally.
degraded(3)
A temperature sensor, fan or other power supply component is
outside of normal operating range.
failed(4)
A power supply component detects a condition that could
permanently damage the system.
0
HP System Summary
HP SNMP Agent Condition
{Template SNMP HP Server Summary exp:cpqHeFltTolPowerSupplyCondition.["{#SNMPINDEX}"].last()}<>2 and {Template SNMP HP Server Summary exp:cpqHeFltTolPowerSupplyCondition.["{#SNMPINDEX}"].last()}<>1
{HOST.NAME}: Power Supply {#SNMPINDEX} Condition is Not OK
0
3
0
Temperature Sensor
4
{$SNMP_COMMUNITY}
.1.3.6.1.4.1.232.6.2.6.8.1.2
snmp.discovery.v3
3600
0
0
0
0
0
161
0
7
Temperature Sensor {#SNMPINDEX} Celsius
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}
cpqHeTemperatureCelsius.["{#SNMPINDEX}"]
600
7
30
0
3
0
0
0
0
1
0
0
161
0
HP Temperature Sensor
HP SNMP Agent Locale
Temperature Sensor {#SNMPINDEX} Locate
4
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.232.6.2.6.8.1.3.{#SNMPINDEX}
cpqHeTemperatureLocale.["{#SNMPINDEX}"]
86400
7
30
0
3
0
0
0
0
1
0
0
161
0
HP Temperature Sensor
HP SNMP Agent Locale
{Template SNMP HP Server Summary exp:cpqHeResilientMemCondition.0.last(0)}>2
{HOST.NAME}: Resilient Memory Condition is Not OK
0
1
0
{Template SNMP HP Server Summary exp:cpqHeMibCondition.0.last(0)}<>2
{HOST.NAME}: Server Condition is Not OK
1
3
The overall condition. This object represents the overall status of the server health system represented by this MIB.
0
{Template SNMP HP Server Summary exp:cpqHeThermalCondition.0.last(0)}<>2
{HOST.NAME}: Termal Condition is Not OK
0
3
0
{Template SNMP HP Server Summary exp:cpqHeMibCondition.0.nodata(3600)}=1
{HOST.NAME} no SNMP data
0
2