2.0
2012-09-26T16:25:41Z
SNMP
Templates
Template HP ML310G5 SNMP Agent
Template HP ML310G5 SNMP Agent
SNMP
Templates
HP Drive Array
HP SNMP Agent
-
Blade Random Write Rate % of Max
15
0
RandomWriteRatePctMax
60
30
365
0
0
%
0
0
1
avg("cpqDaPhyDrvWrites.2.0",#3) / 200
0
0
Sectors Written (low).
The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical disk drive during the reference hours (phyDrvRefHours).
The actual number of sectors written equals the phyDrvHWrites times 2^32 plus the phyDrvWrites.
This information may be useful for determining rates. For instance, if you wanted to calculate the average number of writes per hour of operation, divide this number by the reference hours.
0
-
Drive 0 Total Bytes Read
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.5.1.1.11.2.0
cpqDaPhyDrvReads.0
60
30
365
0
3
B
0
0
512
0
0
161
0
HP Drive Array
-
Drive 0 Total Bytes Written
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.5.1.1.13.2.0
cpqDaPhyDrvWrites.0
60
30
365
0
3
B
0
0
512
0
0
161
0
HP Drive Array
-
Drive 1 Total Bytes Read
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.5.1.1.11.2.1
cpqDaPhyDrvReads.1
60
30
365
0
3
B
0
0
512
0
0
161
0
HP Drive Array
-
Drive 1 Total Bytes Written
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.5.1.1.13.2.1
cpqDaPhyDrvWrites.1
60
30
365
0
3
B
0
0
512
0
0
161
0
HP Drive Array
-
Drive Array Accelerator Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.2.1.9.2
cpqDaAccelCondition.2
600
90
365
0
3
0
0
1
0
0
161
The condition of the device. This value represents the overall condition of this array accelerator.
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Array Accelerator Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.2.1.2.2
cpqDaAccelStatus.2
600
90
365
0
3
0
0
1
0
0
161
Array Accelerator Board Status.
This describes the status of the accelerator write cache.
The status can be:
Other (1)
Indicates that the instrument agent does not recognize the
status of the Array Accelerator. You may need to upgrade
the instrument agent.
Invalid (2)
Indicates that an Array Accelerator board has not been
installed in this system or is present but not configured.
Enabled (3)
Indicates that write cache operations are currently configured
and enabled for at least one logical drive.
Temporarily Disabled (4)
Indicates that write cache operations have been temporarily
disabled. View the Array Accelerator Board Error Code object
to determine why the write cache operations have been
temporarily disabled.
Permanently Disabled (5)
Indicates that write cache operations have been permanently
disabled. View the Array Accelerator Board Error Code object
to determine why the write cache operations have been disabled.
0
HP Drive Array
-
Drive Array Accelerator Write Cache %
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.2.1.14.2
cpqDaAccelWriteCachePercent.2
600
7
365
0
3
%
0
0
1
0
0
161
Write Cache Percent.
This shows the percent of cache memory allocated for posted write caching. If the data cannot be determined or is not applicable, the value is set to 4,294,967,295.
0
HP Drive Array
-
Drive Array Controller Firmware Revision
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.1.1.3.2
cpqDaCntlrFWRev.2
86400
365
365
0
4
0
0
1
0
0
161
Array Controller Firmware Revision.
The firmware revision of the drive array controller. This value can be used to help identify a particular revision of the controller.
0
HP Drive Array
-
Drive Array Controller Model
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.1.1.2.2
cpqDaCntlrModel.2
86400
30
0
0
3
0
0
1
0
0
161
Array Controller Model.
The type of controller card.
0
HP Drive Array
-
Drive Array Logical Drive Avg Latency
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.3.2.7.1.1.7.2.1
cpqDaCntlrPerfAvgLatency.2.1
600
90
365
0
0
ms
0
0
.01
0
0
161
Array Controller Performance Monitor Average Command Latency.
This value shows the average command latency for this sample in 1/10,000 second units.
0
HP Drive Array
-
Drive Array Logical Drive Avg Queue Depth
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.8.1.1.5.2.1.1
cpqDaLogDrvPerfAvgQueueDepth.2.1.1
600
90
365
0
3
0
0
1
0
0
161
Array Logical Drive Performance Monitor Average Queue Depth.
This value indicates the average command queue depth of the logical volume.
0
HP Drive Array
-
Drive Array Logical Drive Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.3.1.1.11.2.1
cpqDaLogDrvCondition.2.1
600
90
365
0
3
0
0
1
0
0
161
The Logical Drive condition.
This value represents the overall condition of this logical drive and any associated physical drives.
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Array Logical Drive Fault Tolerance
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.3.1.1.3.2.1
cpqDaLogDrvFltTol.2.1
600
90
365
0
3
0
0
1
0
0
161
Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive. The following values are valid for the Logical Drive Fault Tolerance:
None (2)
Fault tolerance is not enabled. If a physical drive reports
an error, the data cannot be recovered by the drive array
controller.
Mirroring (3)
For each physical drive, there is a second physical drive
containing identical data. If a drive fails, the data can be
retrieved from the mirror drive.
Data Guard (4)
One of the physical drives is used as a data guard drive and
contains the exclusive OR of the data on the remaining drives.
If a failure is detected, the drive array controller rebuilds
the data using the data guard information plus information
from the other drives.
Distributed Data Guard (5)
Distributed Data Guarding, sometimes referred to as RAID 5,
is similar to Data Guarding, but instead of storing the parity
information on one drive, the information is distributed across
all of the drives. If a failure is detected, the drive array
controller rebuilds the data using the data guard information
from all the drives.
Advanced Data Guarding (7)
Advanced Data Guarding (RAID ADG) is the fault tolerance method
that provides the highest level of data protection. It
'stripes' data and parity across all the physical drives in the
configuration to ensure the uninterrupted availability of
uncorrupted data. This fault-tolerance method is similar to
distributed data guard (RAID 5) in that parity data is
distributed across all drives in the array, except in RAID ADG
the capacity of multiple drives is used to store parity data.
Assuming the capacity of 2 drives is used for parity data,
this allows continued operation despite simultaneous failure of
any 2 drives in the array, whereas RAID 4 and RAID 5 can only
sustain failure of a single drive.
0
HP Drive Array
-
Drive Array Logical Drive Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.3.1.1.4.2.1
cpqDaLogDrvStatus.2.1
600
90
365
0
3
0
0
1
0
0
161
Logical Drive Status.
The logical drive can be in one of the following states:
Ok (2)
Indicates that the logical drive is in normal operation mode.
Failed (3)
Indicates that more physical drives have failed than the
fault tolerance mode of the logical drive can handle without
data loss.
Unconfigured (4)
Indicates that the logical drive is not configured.
Recovering (5)
Indicates that the logical drive is using Interim Recovery Mode.
In Interim Recovery Mode, at least one physical drive has
failed, but the logical drive's fault tolerance mode lets the
drive continue to operate with no data loss.
Ready Rebuild (6)
Indicates that the logical drive is ready for Automatic Data
Recovery. The physical drive that failed has been replaced,
but the logical drive is still operating in Interim Recovery
Mode.
Rebuilding (7)
Indicates that the logical drive is currently doing Automatic
Data Recovery. During Automatic Data Recovery, fault tolerance
algorithms restore data to the replacement drive.
Wrong Drive (8)
Indicates that the wrong physical drive was replaced after a
physical drive failure.
Bad Connect (9)
Indicates that a physical drive is not responding.
Overheating (10)
Indicates that the drive array enclosure that contains the
logical drive is overheating. The drive array is still
functioning, but should be shutdown.
Shutdown (11)
Indicates that the drive array enclosure that contains the
logical drive has overheated. The logical drive is no longer
functioning.
Expanding (12)
Indicates that the logical drive is currently doing Automatic
Data Expansion. During Automatic Data Expansion, fault
tolerance algorithms redistribute logical drive data to the
newly added physical drive.
Not Available (13)
Indicates that the logical drive is currently unavailable.
If a logical drive is expanding and the new configuration
frees additional disk space, this free space can be
configured into another logical volume. If this is done,
the new volume will be set to not available.
Queued For Expansion (14)
Indicates that the logical drive is ready for Automatic Data
Expansion. The logical drive is in the queue for expansion.
0
HP Drive Array
-
Drive Array Physical Drive 0 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.37.2.0
cpqDaPhyDrvCondition.2.0
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Array Physical Drive 0 Reads/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.11.2.0
cpqDaPhyDrvReads.2.0
60
30
365
0
3
reads/s
1
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 0 Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.6.2.0
cpqDaPhyDrvStatus.2.0
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 0 Writes/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.13.2.0
cpqDaPhyDrvWrites.2.0
60
30
365
0
3
writes/s
1
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 1 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.37.2.1
cpqDaPhyDrvCondition.2.1
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Array Physical Drive 1 Reads/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.11.2.1
cpqDaPhyDrvReads.2.1
60
30
365
0
3
reads/s
1
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 1 Status
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.6.2.1
cpqDaPhyDrvStatus.2.1
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 1 Writes/Sec
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.13.2.1
cpqDaPhyDrvWrites.2.1
60
30
365
0
3
writes/s
1
0
1
0
0
161
0
HP Drive Array
-
Drive Array Physical Drive 2 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.37.2.2
cpqDaPhyDrvCondition.2.2
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Array Physical Drive 3 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.5.1.1.37.2.3
cpqDaPhyDrvCondition.2.3
600
90
365
0
3
0
0
1
0
0
161
0
HP Drive Array
HP SNMP Agent Condition
-
Drive Write Cache State
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.3.2.2.1.1.27.2
cpqDaCntlrDriveWriteCacheState.2
600
365
365
0
3
0
0
1
0
0
161
0
HP SNMP Agent
-
Enclosure Name !!!
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.2.2.13.1.1.8.1
cpqSiRackEnclosureMgrName.1
86400
30
365
1
4
0
0
1
0
0
161
!!!
28
HP SNMP Agent
-
Fault Tolerant Fan 0 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.6.7.1.9.0.1
cpqHeFltTolFanCondition.0.1
600
90
365
0
3
0
0
1
0
0
161
The condition of the fan.
This value will be one of the following: other(1)
Fan status detection is not supported by this system or driver.
ok(2)
The fan is operating properly.
degraded(2)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly.
0
HP SNMP Agent
HP SNMP Agent Condition
-
Fault Tolerant Fan 2 Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.6.7.1.9.0.3
cpqHeFltTolFanCondition.0.3
600
90
365
0
3
0
0
1
0
0
161
The condition of the fan.
This value will be one of the following: other(1)
Fan status detection is not supported by this system or driver.
ok(2)
The fan is operating properly.
degraded(2)
A redundant fan is not operating properly.
failed(4)
A non-redundant fan is not operating properly.
0
HP SNMP Agent
HP SNMP Agent Condition
-
Firmware 0 DisplayName
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.4.0
cpqHoFwVerDisplayName.0
86400
30
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 0 Version
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.5.0
cpqHoFwVerVersion.0
86400
365
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 1 DisplayName
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.4.1
cpqHoFwVerDisplayName.1
86400
30
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 1 Version
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.5.1
cpqHoFwVerVersion.1
86400
365
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 2 DisplayName
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.4.2
cpqHoFwVerDisplayName.2
86400
30
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 2 Version
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.5.2
cpqHoFwVerVersion.2
86400
365
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 3 DisplayName
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.4.3
cpqHoFwVerDisplayName.3
86400
30
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Firmware 3 Version
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.11.2.14.1.1.5.3
cpqHoFwVerVersion.3
86400
365
365
0
4
0
0
1
0
0
161
0
HP SNMP Agent
-
Health MIB Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.1.3.0
cpqHeMibCondition.0
600
90
365
0
3
0
0
1
0
0
161
The overall condition (status) of the system represented by this MIB.
0
HP SNMP Agent
HP SNMP Agent Condition
-
Memory Module Size 1
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.1
cpqSiMemModuleSize.0.1
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 2
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.2
cpqSiMemModuleSize.0.2
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 3
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.3
cpqSiMemModuleSize.0.3
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 4
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.4
cpqSiMemModuleSize.0.4
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 5
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.5
cpqSiMemModuleSize.0.5
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 6
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.6
cpqSiMemModuleSize.0.6
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 7
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.7
cpqSiMemModuleSize.0.7
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Memory Module Size 8
4
{$SNMP_COMMUNITY}
1
1.3.6.1.4.1.232.2.2.4.5.1.3.0.8
cpqSiMemModuleSize.0.8
86400
7
365
0
3
B
0
0
1024
0
0
161
0
HP SNMP Agent
-
Product Name
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.2.2.4.2.0
cpqSiProductName.0
86400
30
365
0
4
0
0
1
0
0
161
29
HP SNMP Agent
-
Resilient Memory Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.14.4.0
cpqHeResilientMemCondition.0
600
90
365
0
3
0
0
1
0
0
161
This value specifies the current condition of the Advanced Memory Protection subsystem.
The following states are supported:
other(1)
The system does not support fault tolerant memory or the
state cannot be determined by the Management Agent.
ok(2)
This system is operating normally.
degraded(3)
The system is running in a degraded state because the
Advanced Memory Protection subsystem has been engaged.
0
HP SNMP Agent
HP SNMP Agent Condition
-
Thermal Condition
4
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.232.6.2.6.1.0
cpqHeThermalCondition.0
600
90
365
0
3
0
0
1
0
0
161
This value specifies the overall condition of the system's thermal environment.
0
HP SNMP Agent
HP SNMP Agent Condition
{Template HP ML310G5 SNMP Agent:cpqDaAccelCondition.2.last(0)}#2
{HOST.NAME}: Drive Array Accelerator Condition is Not OK ({ITEM.LASTVALUE})
0
1
0
{Template HP ML310G5 SNMP Agent:cpqDaLogDrvCondition.2.1.last(0)}#2
{HOST.NAME}: Drive Array Logical Drive Condition is Not OK
0
1
0
{Template HP ML310G5 SNMP Agent:cpqDaPhyDrvCondition.2.0.last(0)}#2
{HOST.NAME}: Drive Array Physical Drive 0 Condition is Not OK
0
4
0
{Template HP ML310G5 SNMP Agent:cpqDaPhyDrvCondition.2.1.last(0)}#2
{HOST.NAME}: Drive Array Physical Drive 1 Condition is Not OK
0
4
0
{Template HP ML310G5 SNMP Agent:cpqDaPhyDrvCondition.2.2.last(0)}#2
{HOST.NAME}: Drive Array Physical Drive 2 Condition is Not OK
0
4
0
{Template HP ML310G5 SNMP Agent:cpqDaPhyDrvCondition.2.3.last(0)}#2
{HOST.NAME}: Drive Array Physical Drive 3 Condition is Not OK
0
4
0
{Template HP ML310G5 SNMP Agent:cpqHeFltTolFanCondition.0.1.last(0)}>2
{HOST.NAME}: Fault Tolerant Fan 0 Condition is Not OK
0
1
0
{Template HP ML310G5 SNMP Agent:cpqHeFltTolFanCondition.0.3.last(0)}>2
{HOST.NAME}: Fault Tolerant Fan Condition is Not OK
0
1
0
{Template HP ML310G5 SNMP Agent:cpqHeMibCondition.0.last(0)}#2
{HOST.NAME}: Health MIB Condition is Not OK
1
1
0
{Template HP ML310G5 SNMP Agent:cpqHeResilientMemCondition.0.last(0)}#2
{HOST.NAME}: Resilient Memory Condition is Not OK
0
1
0
{Template HP ML310G5 SNMP Agent:cpqHeThermalCondition.0.last(0)}#2
{HOST.NAME}: Thermal Condition is Not OK
0
1
0