2.0
2012-09-26T16:12:39Z
Templates
UPS devices
Template APC Battery
Template APC Battery
Templates
UPS devices
Battery Data
Inventory Data
-
APC: Basic Output Status
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.4.1.1.0
upsBasicOutputStatus
30
7
365
0
3
0
0
1
0
0
The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1).
0
Battery Data
APC Basic Output Status
-
APC: Battery Capacity (%)
1
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.318.1.1.1.2.2.1.0
upsAdvBatteryCapacity
30
7
365
0
0
0
0
1
0
0
The remaining battery capacity expressed in percent of full capacity.
0
Battery Data
-
APC: Battery Status
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.2.1.1.0
upsBasicBatteryStatus
30
7
365
0
3
0
0
1
0
0
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime.
0
Battery Data
APC Battery Status
-
APC: Battery Temperature
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.2.2.2.0
upsAdvBatteryTemperature
30
7
365
0
3
0
0
1
0
0
The current internal UPS temperature expressed in Celsius.
0
Battery Data
-
APC: Date Of Manufacture
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.1.2.2.0
upsAdvIdentDateOfManufacture
40320
7
365
0
4
0
0
1
0
0
The date when the UPS was manufactured in mm/dd/yy format.
44
Inventory Data
-
APC: Firmware Revision
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.1.2.1.0
upsAdvIdentFirmwareRevision
40320
7
365
0
4
0
0
1
0
0
The firmware revision of the UPS system's microprocessor.
7
Inventory Data
-
APC: Input Voltage
1
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.318.1.1.1.3.2.1.0
upsAdvInputLineVoltage
30
7
365
0
0
0
0
1
0
0
The current utility line voltage in VAC.
0
Battery Data
-
APC: Last Battery Replacement
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.2.1.3.0
upsBasicBatteryLastReplaceDate
40320
7
365
0
4
0
0
1
0
0
The date when the UPS system's batteries were last replaced in mm/dd/yy format. For Smart-UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator.
45
Inventory Data
-
APC: Load Current (Amps)
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.4.2.4.0
upsAdvOutputCurrent
30
7
365
0
0
0
0
1
0
0
The current in amperes drawn by the load on the UPS.
0
Battery Data
-
APC: Model
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.1.1.1.0
upsBasicIdentModel
40320
7
365
0
4
0
0
1
0
0
The UPS model name (e.g. 'APC Smart-UPS 600').
29
Inventory Data
-
APC: Output Frequency
1
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.318.1.1.1.4.2.2.0
upsAdvOutputFrequency
30
7
365
0
0
0
0
1
0
0
The current output frequency of the UPS system in Hz.
0
Battery Data
-
APC: Output Load (%)
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.4.2.3.0
upsAdvOutputLoad
30
7
365
0
0
0
0
1
0
0
The current UPS load expressed in percent of rated capacity.
0
Battery Data
-
APC: Output Voltage
1
{$SNMP_COMMUNITY}
0
1.3.6.1.4.1.318.1.1.1.4.2.1.0
upsAdvOutputVoltage
30
7
365
0
0
0
0
1
0
0
The output voltage of the UPS system in VAC.
0
Battery Data
-
APC: Replace Battery Indicator
1
{$SNMP_COMMUNITY}
0
.1.3.6.1.4.1.318.1.1.1.2.2.4.0
upsAdvBatteryReplaceIndicator
600
7
365
0
3
0
0
1
0
0
Indicates whether the UPS batteries need replacing.
0
Battery Data
APC Battery Replace Indicator
-
APC: Run Time Remaining
1
{$SNMP_COMMUNITY}
1
.1.3.6.1.4.1.318.1.1.1.2.2.3.0
upsAdvRunTimeRemaining
30
7
365
0
3
s
0
0
0.01
0
0
The UPS battery run time remaining before battery exhaustion.
0
Battery Data
-
APC: Time On Battery
1
{$SNMP_COMMUNITY}
1
.1.3.6.1.4.1.318.1.1.1.2.1.2.0
upsBasicBatteryTimeOnBattery
30
7
365
0
3
s
0
0
0.01
0
0
The elapsed time since the UPS has switched to battery power.
0
Battery Data
{Template APC Battery:upsAdvRunTimeRemaining.max(60)}<300
APC: Battery time left: <5 minutes - {HOST.NAME}
0
5
0
{Template APC Battery:upsAdvRunTimeRemaining.max(120)}<600
APC: Battery time left: <10 minutes - {HOST.NAME}
0
4
0
{Template APC Battery:upsAdvBatteryTemperature.last(0)}>42
APC: High Battery Temperature - {HOST.NAME}
0
5
0
{Template APC Battery:upsBasicBatteryStatus.last(0)}#2
APC: Loss of Input Power - {HOST.NAME}
0
5
0
{Template APC Battery:upsAdvOutputLoad.last(0)}>90
APC: Output Load Too High - {HOST.NAME}
0
2
0
{Template APC Battery:upsAdvBatteryReplaceIndicator.last(0)}#1
APC: Replace Battery - {HOST.NAME}
0
5
0
{Template APC Battery:upsBasicOutputStatus.last(0)}=3
APC: Running on battery - {HOST.NAME}
0
4
0
Battery Status
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
1
0
0
0
0
0
C80000
0
2
0
-
Template APC Battery
upsBasicBatteryStatus
1
0
00C800
0
2
0
-
Template APC Battery
upsAdvBatteryReplaceIndicator
Load
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
0
0
0
0
0
0
C80000
0
2
0
-
Template APC Battery
upsAdvOutputCurrent
1
0
00C800
0
2
0
-
Template APC Battery
upsAdvOutputLoad
Temperature
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
1
0
0
0
0
5
C80000
0
2
0
-
Template APC Battery
upsAdvBatteryTemperature
Voltage
900
200
0.0000
100.0000
1
1
0
1
0
0.0000
0.0000
0
0
0
0
0
0
C80000
0
2
0
-
Template APC Battery
upsAdvOutputVoltage
1
0
00C800
0
2
0
-
Template APC Battery
upsAdvInputLineVoltage